12.8.6
Terminating Resistor
TERMINATION [OFF|ON]
Defines whether a terminating resistor is connected in the synchronization line in order to avoid reflections.
OFF: No terminating resistor
●
ON: Terminating Resistor
12.9
Parameter Management, Load/Save Settings
12.9.1
Basic Settings
BASICSETTINGS READ | STORE
READ: Basic (connection) settings are read from the memory
●
STORE: Basic (connection) settings are stored in the memory
●
12.9.2
Output of Changed Settings
CHANGESETTINGS
MEASSETTINGS is output if any parameters in the measurement settings have changed since the MEASSETTINGS
●
STORE command was last executed.
BASICSETTINGS is output if any parameters in the basic settings have changed since the BASICSETTINGS STORE
●
command was last executed.
12.9.3
Exporting Sensor Settings
EXPORT (MEASSETTINGS <SettingName>) | BASICSETTINGS | MEASSETTINGS_ALL | ALL
Exports the sensor settings.
MEASSETTINGS: Exports the measurement settings with the name <SettingName>
●
BASICSETTINGS: Exports the basic settings only
●
MEASSETTINGS_ALL: Exports all measurement settings
●
ALL: Exports all basic and measurement settings
●
12.9.4
Importing Sensor Settings
IMPORT [FORCE] [APPLY] <ImportData>
Imports settings into the sensor.
FORCE: Allows existing settings to be overwritten
●
APPLY: Applies the imported settings
●
ImportData: Data in JSON format
●
12.9.5
Factory Reset
SETDEFAULT ALL | MEASSETTINGS | BASICSETTINGS
Resets the sensor to its factory settings.
ALL: Deletes all settings and loads the factory settings
●
MEASSETTINGS: Deletes all measurement settings
●
BASICSETTINGS: Deletes all basic settings
●
optoCONTROL 2700
ASCII Communication
Seite 88
Need help?
Do you have a question about the optoCONTROL 2700 and is the answer not in the manual?