12.14.6
Switching Output Hold Period
ERROROUTHOLD1 <hold period [ms]>
ERROROUTHOLD2 <hold period [ms]>
ERROROUTHOLD3 <hold period [ms]>
This command defines the minimum hold period for the limit value of the ERROROUT1, ERROROUT2, ERROROUT3
commands.
See also:
ERRORLIMITVALUES1
ERRORLIMITVALUES2
ERRORLIMITVALUES3
<hold period [ms]> = 0 ... 10000 [ms]
●
12.14.7
Switching Behavior of Error Outputs
ERRORLEVELOUT1 [NPN|PNP|PUSHPULL|PUSHPULLNEG]
ERRORLEVELOUT2 [NPN|PNP|PUSHPULL|PUSHPULLNEG]
ERRORLEVELOUT3 [NPN|PNP|PUSHPULL|PUSHPULLNEG]
This command defines the output type for the relevant switching output or displays the current setting.
12.15
Analog Output
12.15.1
Selecting the Signal for the Analog Output
ANALOGOUT [<signal>]
Select a signal for the analog output
signal: Signal selected for output. The META_ANALOGOUT command lists all the signals available for an output.
●
12.15.2
Possible Signals for Analog Output
META_ANALOGOUT
Lists the available signals that can be used for the ANALOGOUT command.
12.15.3
Selecting the Output Range for the Analog Output
ANALOGRANGE [0-5V|0-10V|4-20MA]
Defines the output range for the analog output.
0-5 V: Measured value is specified in the 0-5 V range.
●
0-10 V: Measured value is specified in the 0-10 V range.
●
4-20mA: Measured value is specified in the 0-20 mA range.
●
12.15.4
Scaling of the Analog Output
ANALOGSCALEMODE [STANDARD|TWOPOINT]
Set or adjust the scaling of the analog output.
STANDARD: Use measuring range of sensor
●
TWOPOINT: The measured values are scaled to the range specified by the ANALOGSCALERANGE command.
●
optoCONTROL 2700
ASCII Communication
Seite 98