Control Branch; Control Branch Menu Options - Paradyne 3610 Application Manual

Data service units time division multiplexer, multichannel multipoint, and digital bridge options
Hide thumbs Also See for 3610:
Table of Contents

Advertisement

Control Branch

The Control (Ctrl) branch allows you to enable or
disable the DSU's transmitter, as well as the DBM's, and
to display/change the status of the general purpose
external DTE leads.* For a DSU operating in TDM or
MCMP mode, the Control branch allows the transmitter to
be enabled or disabled on a per-port basis. It also allows
you to choose which of the six ports is to have its circuit
leads monitored.
When in TDM or MCMP mode, the following
selections appear:
Control Funct:
TxCt l
LEDs
F1
F2
*DSU and DBM subbranches are valid for Local mode only; Devic and Ports are displayed for Remote mode. Also, if
General configuration option Ext Leads is set to ExtLd, Chang is not displayed.
3610-A2-GB41-70
ExtL
F3
July 1999
When in Bridge mode, the following selections appear:
Control Funct:
LEDs
ExtL
F1
F2
When in Basic mode, the following selections appear:
Control Funct:
TxCt l
ExtL
F1
F2
A DBM can be disabled if it is addressed from the
Remote branch. The Control branch menu has three
selections. Table 5-13 lists the selections on the Control
branch menu.
Table 5-13

Control Branch Menu Options

Menu
Selection
TxCtl
Enables or disables the DSU's
transmitter, or the DBM's call
setup or answer capability.
LEDs
Selects whether the port or
aggregate data stream is
monitored on the faceplate
1
LEDs.
ExtL
Provides status and control of
two external input leads and two
output leads available for
optional customer assignment.
1
Only applies to TDM or MCMP applications, and
only in Local mode.
Refer to the COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611, Operator's Guide for
additional information and examples.
DSU Operations
F3
F3
Purpose
5-43