Troubleshooting

Starting/Stopping Other Loopbacks

"
OCU-DP Local Loopback Tests
9-38
Procedure
To start and stop loopback tests:
1. Follow this menu selection sequence to display the Tests screen:
Main Menu
Test
2. For Nonlatching loopbacks, select the desired loopback type (CSU or DSU).
3. Highlight Start under Command in the selected test's row. Then, press Enter
to start the test. This field now displays the word Stop.
4. View the length of time that the test has been running in the Result column.
5. Highlight Stop under Command in the selected test's row. Then, press Enter
to stop the test. This field now displays the word Start.
The following local loopback tests are available for the OCU-DP APM:
H
Latching Loopback
– applicable only to the 64 Clear Channel DDS (64KCC)
rate
H
Nonlatching Loopback
H
OCU Loopback
H
DS-0 Loopback
H
Line Loopback
H
Data Loopback
[OCU-DP Tests]
– applicable only to the DDS rate of 56K
April 1999
9161-A2-GH30-40