Paradyne 9161 User Manual page 148

Zhone 9161 mux: user guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

Displaying System Information
7-6
View this field . . .
For the FXS Voice APM
Port Status
Assigned To
Operating Mode
Signaling Type
Call Progress
TX ABCD bits
RX ABCD bits
T-R Control
T-R Receive
Trunk Cond CGA
April 1999
To find the . . .
Status of the port.
Interface the port is assigned to.
Operating mode of the voice port that was configured
using the Operating Mode configuration option on the
Voice Ports screen. See the Technical Reference for
configuration information.
Type of signaling used by the voice port that was
configured using the Signaling Type configuration option
on the Voice Ports screen. See the Technical Reference
for configuration information.
Current condition of the port.
Current value of the ABCD signaling bits that are being
transmitted to the T1 interface.
Current value of the ABCD signaling bits that are being
received from the T1 interface.
Current status of the tip and ring leads:
H
RbTo. A – 48 Vdc battery is applied to the Ring lead
and the Tip lead is opened
H
RbTg. A – 48 Vdc battery is applied to the Ring lead
and the Tip lead is grounded
H
TbRg. A – 48 Vdc battery is applied to the Tip lead
and the Ring lead is grounded
H
Ring. Ringing voltage is applied between Tip and
Ring
Status of what the attached device is doing with the Tip
and Ring leads of the FXS port.
H
Loop. Tip and Ring are connected together
H
Rgnd. Ring lead is grounded by attached device
H
Open. Ring lead is not connected to either the Tip
lead or the ground
Displays the status of trunk conditioning (On for CGA,
Off for no CGA).
9161-A2-GH30-40