Aborting Loopbacks - Paradyne 3350 User Manual

Zhone acculink 3350 ntu: user guide
Hide thumbs Also See for 3350:
Table of Contents

Advertisement

ACCULINK 3350 E1 NTU
3. From the Loopback screen, press the
the RLB selection appears on the screen.
Loopback:
Abort
F1
4. Select RLB.
Loopback:
PLB
F1
Test Started appears on Line 2. If a Repeater
loopback is already in progress, the Already
Active message appears. If an invalid combination
of loopbacks is in progress, the error message
Invld Test Combo appears (see Table4-9 for valid
loopback test combinations).

Aborting Loopbacks

The Abort Loopback command stops all loopback tests
or any selected loopback test currently active on the E1
NTU.
To abort one or more loopback tests,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
Test:
Lpbk
F1
4-18
key until
LLB
PLB
F2
F3
DLB
RLB
F2
F3
Ptrns
Lamp
F2
F3
June 1996
3. From the Loopback screen, select Abort.
Loopback:
Abort
LLB
F1
F2
4. From the Loopback Abort screen, press the
desired Function key to abort All or one specific
loopback test. Use the scroll keys, if necessary.
Loopback: Abort
All
LLB
F1
F2
When abort is complete, the message Command
Complete appears on the Abort screen.
NOTE
Be careful when selecting a
specific loopback test to abort. If
you mistakenly choose to abort a
loopback test that is not currently
running, a Command Complete
message will still display and the
loopback that is currently active
will still be running. You can use
the TStat branch of the menu to
view the test status to determine if
the abort was successful.
PLB
F3
PLB
F3
3350-A2-GB20-10

Advertisement

Table of Contents
loading

Table of Contents