Paradyne 9161 User Manual page 122

Zhone 9161 mux: user guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

Setting Up
5-68
Table 5-14. Communication Protocol Options (2 of 3)
Default Network Destination
Possible Settings: None, COM, FDL1, FDL2, DDL, EDL ss - p
Default Setting: None
Specifies where the default network is connected.
H
Default Network Destination is forced to None if:
– Default Network Destination is set to FDL1, FDL2 or DDL and Network
Interface is set to Disable on the Network Interface Options screen (see
Table
5-1).
– Management Link on the Network Interface Options screen is changed to a
value inconsistent with the value of Network Interface Destination.
– Default Network Destination is set to COM and COM Port Use is set to
Terminal or Alarms on the Communication Port Options screen (see
Table
5-10).
– Default Network Destination is set to EDL ss - p and EDL Management Link is
set to Disable on the Synchronous Data Port Options screen for Port p of
Slot ss (see
Table
None – No default network destination. Data that cannot be routed is discarded.
COM – The communication port is the default network destination. This selection only
appears if Port Use is set to Net Link on the Communication Port Options screen (see
Table
5-10).
FDL1 – The FDL is the default network destination on Network Interface 1. This
selection only appears if Management Link is set to FDL on the Network Interface 1
Options screen (see
Table
FDL2 – The FDL is the default network destination on Network Interface 2. This
selection only appears if Management Link is set to FDL on the Network Interface 2
Options screen (see
Table
DDL – The DDL is the default network destination. This selection only appears if
Management Link is set to DDL on the Network Interface Options screen (see
Table
5-1).
EDL ss - p –The EDL- ss - p port (where ss is the slot number of the NAM or the
synchronous data APM belonging to the ports, and p is the number of the port). This
selection only appears if EDL Management Link is set to Enable on the Synchronous
Data Port Options screen (see
Communication Port IP Address
Possible Settings: 000.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the IP address needed to access the unit when the COM port is configured as
a network communication link. The IP address is only in effect when the Communication
Port Use configuration option is set to Net Link (see
000.000.000.000 – 223.255.255.255 – Shows the communication port IP address,
which you can view or edit. The first digit (i.e., xxx .255.255.255) cannot be 0 or 127, or
greater than 223. However, 000 is valid, representing a null address.
Clear – Clears the IP address for the communication port and fills the address with
zeros (i.e., 000.000.000.000).