Copying Port Configurations

"
9161-A2-GH30-40
Copy Ports provides an easy way to configure similar ports. Only enabled ports
may be copied. They may be copied to either enabled or disabled ports.
Procedure
1. Follow this menu selection sequence:
Configuration Edit/Display
2. The Copy Ports screen appears. Select the desired slot number to copy
configuration options from. Upon entering the screen, the slot number of the
T1 NAM is displayed. Use the spacebar to cycle through the slots. You can
also type in the desired slot number.
3. Select the desired port number to copy configuration options from. Use the
spacebar to cycle through the ports available on the card in the selected slot.
Only slots matching the type shown in the From: field are displayed. You can
also type in the desired slot number.
4. Repeat Steps 2 and 3 to select the slot and port to copy configuration options
to.
5. Press Enter to begin the copy process.
If the . . .
Copy To slot and Copy To port
are set to a specific slot and
port number
Copy To slot is set to a
specific number and the Copy
To port is set to All
Copy To slot is set to All the
Copy To port is set to a
specific number
Copy To slot and the Copy To
port are both set to All
6. Select Perform Copy Then Increment if you want to automatically change
the values to the next higher port of the same type. If the last port of the
highest slot was specified, the value will change to Port 1 of the lowest slot
containing the same port type.
Copy Ports
Then the . . .
Copy To slot and port configuration options are
replaced by the Copy From slot and port
configurations options.
Configuration options of all ports on the Copy To
slot are replaced by the Copy From slot and port
configuration options.
Configuration options of the Copy To port of all
slots containing the same type of port (Voice E&M,
Voice FXO, Voice FXS, Sync Data, or OCU-DP) as
on the Copy From slot are replaced by the Copy
From slot and port configuration options.
Configuration options of all ports of all slots
containing the same type of port (Voice E&M, Voice
FXS, Sync Data, or OCU-DP) as on the Copy From
slot are replaced by the Copy From slot and port
configuration options.