Paradyne 9161 User Manual page 306

Zhone 9161 mux: user guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

Technical Specifications
F-6
Specification
Signaling Types
E&M
FXO
FXS
OCU-DP APM
Weight
2-port OCU–DP APM
6-port OCU-DP APM
OCU–DP I/O card
Size
OCU-DP APM
OCU-DP I/O card
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
Power Consumption (max)
2-Port OCU
6-Port OCU
DDS Ports
Standards
Rates
Loopbacks
April 1999
Criteria
Type I
Type II
Type IV
Type V
Loop Start
Loop Start/Forward Disconnect
Ground Start
Loop Start
Loop Start/Forward Disconnect
Ground Start
Ground Start Immediate
Ground Start Automatic
PLAR D3
PLAR D4
0.800 lbs. (.362 kg)
1.052 lbs. (.477 kg)
0.286 lbs. (.130 kg)
11.58 x 8.00 (29.41 cm x 20.32 cm)
2.90 x 10.15 (7.37 cm x 25.78 cm)
35 F to 122 F ( 1.7 C to 50 C )
– 4 F to 158 F (– 20 C to 70 C )
5% to 85% ( noncondensing )
Withstands normal shipping and handling
2.78 watts, 0.232 amps input current at 12 volts
Result: 9.49 BTU per hour
5.04 watts, 0.420 amps input current at 12 volts
Result: 17.20 BTU per hour
AT&T PUB 62310, Bellcore TA-TSY-00077, ANSI
T1.410, AT&T PUB 61330, AT&T TR41458
56 kbps, 64 kbps Clear Channel, 4-wire Switched 56
DS-0, OCU Line, OCU Data, OCU, Local and Remote
Latching and Non-Latching DSU/CSU
9161-A2-GH30-40