Table 5-2. DSX-1 Interface Options (2 of 3)
Line Equalization
Possible Settings: 0–133, 133–266, 266–399, 399–533, 533–655
Default Setting: 0–133
Permits a standard DSX signal to be delivered over a distance of up to 655 feet.
0–133 – Equalization on the DSX-1 side allows up to 133 feet of cable between the
NAM and the DTE.
133–266 – Equalization on the DSX-1 side allows up to 266 feet of cable between the
NAM and the DTE.
266–399 – Equalization on the DSX-1 side allows up to 399 feet of cable between the
NAM and the DTE.
399–533 – Equalization on the DSX-1 side allows up to 533 feet of cable between the
NAM and the DTE.
533–655 – Equalization on the DSX-1 side allows up to 655 feet of cable between the
NAM and the DTE.
Send All Ones on DSX-1 Failure
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether action is taken when a valid signal cannot be recovered for the
DSX-1 (LOS, continuous OOF, or AIS).
Enable – Sends all ones on the DS0 channels allocated to the DSX-1 interface in the
event of an LOS, AIS, or continuous OOS condition on the DSX-1 interface.
Disable – No action is taken when a signal fails on the DSX-1 interface. The data
received is passed through the network interface channels unchanged.
Loss of Signal (LOS) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when a loss of signal condition is
detected on the DSX-1 interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Out of Frame (OOF) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an out-of-frame condition is
detected on the DSX-1 interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.