Displaying System Information

Self-Test Results Messages

7-22
Table 7-2. Health and Status Messages (5 of 5)
Message
What It Indicates
Device Fail yyyyyyyy
The operating software
detects an internal error.
(yyyyyyyy represents an
8-digit hexadecimal failure
code for use by service
personnel) This condition
clears after a reset of the unit.
Module MisConfig,
The APM in slot xx is not the
Slot ss
one specified in the NAM's
configuration table.
Module Unsupported,
The NAM does not recognize
Slot ss
the APM.
A Dual DSX APM has been
installed in a Model 916x T1
Access Unit.
1
ss represents physical slots.
2
Does not apply to the access carrier.
All self-test results messages appear in the middle column of the System and
Test Status screen (see
1, 2
1, 2
Table
7-3).
April 1999
What To Do
Contact your service
representative.
1. Replace the APM with the
type of APM specified by
the configuration table.
2. Change the current
configuration to reflect the
type of APM in the slot. To
do this, edit the
configuration, accept the
APM, then save the
configuration.
1. Check that an E&M Voice
APM, FXS Voice APM,
FXO Voice APM, Dual DSX
APM, or Sync Data APM is
1
installed in Slot ss .
2. For Model 926x T1 Access
Mux, check that there is not
more than one DSX APM
installed (only one is
supported).
3. Re-download the NAM
software if new APMs are
supported in later releases.
4. Replace the APM.
5. Contact your service
representative.
Remove the Dual DSX APM.