9161-A2-GH30-40
Table 7-2. Health and Status Messages (2 of 5)
Message
What It Indicates
OOF at DSX ss-p
An Out of Frame (OOF)
condition is detected on the
DSX-1 interface in slot ss ,
port p .
1. Incompatible framing format
2. DSX-1 cabling problem.
AIS at Network n
An Alarm Indication Signal
(AIS) is received by Network
Interface 1 or 2. AIS is an
unframed, all ones signal.
1. Upstream T1 access unit is
2. The network is transmitting
AIS at DSX ss-p
An Alarm Indication Signal
(AIS) is received by the DSX-1
interface in slot ss , port p . AIS
is an unframed, all ones
signal.
EER at Network n
The error rate of the received
network signal exceeds the
currently configured threshold.
This condition only occurs if
Network Interface 1 or 2 is
configured for ESF framing.
This condition clears when the
error rate falls below the
threshold value.
Yellow at Network n
A yellow alarm signal is
received on Network
Interface 1 or 2.
1. Network cable problem.
2. Far-end T1 access unit has
3. T1 facility problem.
April 1999
between the DTE and the
T1 access unit.
transmitting AIS (keep-alive
signal).
an AIS.
lost framing sync on the T1
line.
Displaying System Information
What To Do
1. Check that the framing
format for the DSX-1 (DTE)
interface is correct.
2. Check that the DSX-1 cable
is securely attached at both
ends.
1. Check status of upstream
T1 access unit(s).
2. Report problem to carrier.
Check the DTE attached to
the DSX-1 interface.
Contact network provider.
1. Check that your network
cable is securely attached
at both ends.
2. Check the status of the
far-end device.
3. Contact your network
provider.
7-19