Troubleshooting
9-14
Table 9-1. ASCII Alarm Messages (2 of 5)
Message
month/day/year
hours:minutes:seconds –
Continuous Loss Of Signal
(LOS) condition detected at
the Network 1/Network 2
Interface or at DSX-1
Interface in slot ss port p .
month/day/year
hours:minutes:seconds –
Alarm Cleared for Loss Of
Signal (LOS) condition at
the Network 1/Network 2
Interface or at the DSX-1
Interface in slot ss port p .
month/day/year
hours:minutes:seconds –
Continuous Out Of Frame
(OOF) detected at the
Network 1/Network 2
Interface or at DSX-1
Interface in slot ss port p .
month/day/year
hours:minutes:seconds –
Alarm Cleared for Out of
Frame (OOF) condition at
the Network 1/Network 2
Interface or at the DSX-1
Interface in slot ss port p .
month/day/year
hours:minutes:seconds –
Continuous Out of Frame
(OOF) condition at
synchronous data port in
slot ss port p .
month/day/year
hours:minutes:seconds –
Alarm Cleared for Out Of
Frame (OOF) condition at
synchronous data port in
slot ss port p .
month/day/year
hours:minutes:seconds –
A DDS Network Failure
code has been received at
OCU-DP port in slot ss
port p .
April 1999
What It Indicates
What To Do
LOS condition
1. Check the cable to
detected.
2. Contact network
Alarm condition no
No action needed.
longer exists.
An out-of-frame
1. Ensure that the line
condition is detected
at the specified
Network or DSX-1
interface.
2. Contact network
Alarm condition no
No action needed.
longer exists.
A continuous
1. Ensure that EDL is
out-of-frame condition
occurred on the
synchronous data port
2. There is a network
for the identified slot
and port.
Alarm condition no
No action needed.
longer exists.
A DDS network failure
Contact the DDS
is being detected on
service provider.
the specified OCU-DP
port.
Priority
2 (Net)
the Network/DSX-1
3 (DSX-1)
interface.
provider.
4 (Net)
framing format
5 (DSX-1)
configuration option
setting matches the
setting of the
equipment (DSX-1)
or network (Net).
provider.
13
enabled on the
far-end port.
problem with the
fractional portion of
the link carrying this
port's data. Contact
network provider.
19
9161-A2-GH30-40