Troubleshooting
9-16
Table 9-1. ASCII Alarm Messages (4 of 5)
Message
month/day/year
hours:minutes:seconds –
Alarm Cleared for a Loss
Of Signal (LOS) at
OCU-DP port in slot ss
port p .
month/day/year
hours:minutes:seconds –
A Module Misconfiguration
condition was detected for
slot ss.
month/day/year
hours:minutes:seconds –
Alarm Cleared for the
Module Misconfiguration for
slot ss .
month/day/year
hours:minutes:seconds –
Power Supply Alarm
condition detect.
month/day/year
hours:minutes:seconds –
Alarm Cleared for Power
Alarm condition.
month/day/year
hours:minutes:seconds –
Yellow alarm signal
received at the Network
1/Network 2 Interface or at
the DSX-1 Interface in
slot ss port p .
month/day/year
hours:minutes:seconds –
Alarm Cleared for Yellow
alarm signal at the
Network1/Network 2
Interface or at the DSX-1
Interface in slot ss port p .
April 1999
What It Indicates
What To Do
Alarm condition no
No action needed.
longer exists.
The identified slot
Ensure that the APM
previously contained a
installed is the correct
different type of APM.
type. If it is not, install
the correct APM type.
The card needs to be
accepted.
Alarm condition no
No action needed.
longer exists.
A power supply or fan
1. Check that the
tray problem is
detected on the
system.
2. Contact your
Alarm condition no
No action needed.
longer exists.
A Yellow alarm signal
1. Check the Network
is detected on the
specified Network or
DSX-1 interface.
2. Contact network
Alarm condition no
No action needed.
longer exists.
Priority
8
1
power supply or fan
tray is mounted
correctly in the
housing.
service
representative.
9 (Net)
and/or DSX-1
10 (DSX-1)
cable.
provider for
Network interface
problem. Check
equipment for
DSX-1 interface
problem.
9161-A2-GH30-40