SNMP Traps
Traps: Enterprise-Specific
Trap
enterpriseAPMFailed(9)
enterpriseAPMFailedClear (109)
enterpriseConfigChange(6)
enterpriseDeviceFail(3)
enterpriseModuleMisConfig (8)
enterpriseModuleMisConfigClear(108)
enterprisePowerSupply(7)
enterprisePowerSupplyClear(107)
enterprisePrimaryClockFail(1)
enterprisePrimaryClockFailClear(101)
enterpriseSecondaryClockFail(4)
enterpriseSecondaryClockFailClear(104) The failure of the device's currently
enterpriseSelfTestFail(2)
enterpriseTestStart(5)
enterpriseTestStop(105)
C-4
These traps indicate that an enterprise-specific event has occurred. Supported
enterprise-specific traps include the following, listed in alphabetical order:
What It Indicates
The APM cannot be detected.
The APM failure has cleared.
Configuration has been changed
via the user interface or an SNMP
Manager after 60 seconds has
elapsed without another change.
An internal device failure.
A module misconfiguration has
been detected.
A module misconfiguration error
condition has been cleared.
The power supply output voltage
has dropped below the tolerance
level.
The power supply output voltage
alarm condition has cleared.
A failure of the device's currently
configured primary clock source.
The failure of the device's currently
configured primary clock source
has cleared.
A failure of the device's currently
configured secondary clock
source.
configured secondary clock source
has cleared.
A hardware failure.
A test is running.
All tests have been halted.
April 1999
Possible Cause
The APM has failed or has been
removed.
The APM failure has cleared.
Configuration has been changed
via the user interface or an SNMP
Manager.
Operating software has detected
an internal device failure.
An APM is installed in a slot that
previously contained another type
of APM.
The operating software no longer
detects a misconfiguration.
Power supply problem.
The power supply output voltage
alarm condition has cleared.
Operating software has detected
that the primary clock source has
failed.
Operating software has detected
that the primary clock source is
now operational again.
Operating software has detected
that the secondary clock source
has failed.
Operating software has detected
that the secondary clock source is
now operational again.
Unit has completed (re)initialization
and a hardware failure was
detected.
At least one test has been started
on an interface.
All tests have been halted on an
interface.
9161-A2-GH30-40