Technical Specifications
9161-A2-GH30-40
Specification
Network Access Module (NAM)
Approvals
FCC Part 15
FCC Part 68
Industry Canada
UL
CSA – Safety
Weight
T1 NAM
T1 I/O Card
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
Power Consumption
April 1999
Criteria
Class A digital device.
Refer to the equipment's label for the
Registration Number.
Refer to the equipment's label for the
Certification Number.
Refer to the equipment's label for the UL listing.
Refer to the equipment's label for CSA safety
information.
1 lb. 2 oz. ( .510 kg )
6 oz. (.170 kg)
35 F to 122 F ( 1.7 C to 50 C )
– 4 F to 158 F (– 20 C to 70 C )
5% to 85% ( noncondensing )
Withstands normal shipping and handling
9.4 watts, 0.78 amps input current at 12 volts
Result: 32.07 BTU per hour