Device Name: ___________________________________________________________
9161-A2-GH30-40
DSX-1
Configuration Option
Slot ss
Port p
Interface Status
Line Framing Format
Line Coding Format
Line Equalization
Send All Ones on DSX-1 Failure
Loss of Signal (LOS) Alarm
Out of Frame (OOF) Alarm
Alarm Indication Signal (AIS)
Yellow Alarm
April 1999
Menus and Configuration Worksheets
See Table 5-2
Settings
916x: 01
9262: 02
9265: 02, 03, 04, 05
916x: 1
926x: 1, 2
Enable, [Disable]
D4, [ESF]
AMI, [B8ZS]
[0–133], 133–266, 266–399, 399–533, 533–655
[Enable], Disable
[Enable], Disable
[Enable], Disable
[Enable], Disable
[Enable], Disable
Default in [Bold]
A-5