H Ocu-Dp Tests; Sending A Latching Loopback - Paradyne 9161 User Manual

Zhone 9161 mux: user guide
Hide thumbs Also See for 9161:
Table of Contents

Advertisement

"
"
OCU-DP Tests

Sending a Latching Loopback

"
9161-A2-GH30-40
Procedure
To force signaling:
1. Follow this menu selection sequence:
Main Menu
Test
2. Enter the desired slot and port number.
3. Press PgDn to go to page 2.
4. Enter the desired setting for each field.
5. Highlight Start under Command in the row to send a test. Then, press Enter
to start the test.
6. View the length of time that the test has been running in the Results column.
7. Highlight Stop under Command to stop the test.
Procedure
To monitor signaling:
1. Follow this menu selection sequence:
Main Menu
Test
2. Enter the desired slot and port number.
3. Press PgDn to go to page 2.
4. Look at the values displayed under the Monitor Signaling portion of the
screen.
The OCU-DP tests run on the OCU-DP APM's ports. The procedure to send a
Latching loopback differs from the procedure to start/stop other loopbacks. Both
procedures are described below.
Procedure
To send a Latching Loopback:
1. Follow this menu selection sequence:
Main Menu
Test
2. Enter the loopback type:
— For Local: CSU or DSU
— For Remote: CSU, DSU, or OCU
3. Select the code Up or Down.
4. Highlight Send in the Command row. Then, press Enter to start the test. The
code will be sent for up to 10 seconds, or until an acknowledgement is
received.
5. View the length of time that the test has been running in the Results column.
6. Send the Down code to stop the loopback.
Voice Port Tests
Voice Port Tests
[OCU-DP Tests]
April 1999
Troubleshooting
9-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

9261

Table of Contents