2.8 Integrated indicator and integrated indicator control panel

2.8.1 General information

Integrated indicator 15 (figure 2.1.1) (further in the text II) and integrated indicator
control panel 16 (figure 2.1.1) (further in the text IICP) display information on operational
parameters of systems and units of the tractor and provide operator with data on violation
of operation or breakdown of any system.
II includes gauges and signal lamps according to figure 2.8.1
1 – velocity gauge (needle indicator); 2 – engine speed gauge (needle indicator); 3 –
RPTO speed gauge (light indicator); 4, 9 – segments of RPTO speed scale (yellow color);
5, 7, 8 – segments of RPTO speed scale (green color); 6 – annunciator of RPTO speed
scale range «540 min
-1
«1000 min
» (yellow color); 11 – pilot lamp to indicate headlights upper beam switching
(blue color); 12 – pilot lamp to indicate switching of trailer turn blinkers (green color); 13 –
pilot lamp to indicate switching of tractor turn blinkers (green color); 14 – pilot lamp to indi-
cate parking brake engagement (red color); 15 – pilot lamp to indicate increased voltage in
on-board system (red color); 16 – pilot lamp to indicate low level of coolant (yellow color);
17- multifunction indicator.
Note – On tractors "BELARUS-2022.6" the pilot lamp to indicate low level of coolant
16 is not used.
While switching on the instrument scale lighting, i.e. while shifting the central dip-
switch control into the position II "Instrument scale lighting, parking lights are on" and the
position III "Consumers of the position II and front road headlights are on", light intensity of
multifunction display and PTO indicator segments is automatically reduced.
The integrated indicator control panel is shown in figure 2.8.2.
-1
» (yellow color); 10 – annunciator of RPTO speed scale range
Figure 2.8.1 – Integrated indicator
Figure 2.8.2 – Integrated indicator control panel