When exiting the mode, the last set parameter values chosen with the "Value" but-
ton are saved.
When choosing an unfixed parameter value of the integrated indicator program-
ming, it is necessary to do the following:
- press the "Parameter" button (figure 2.8.4) to choose the parameter value to be
set;
- press the "Mode" button twice, after which the low-order digit will start blinking on
multifunction indicator 17 (figure 2.8.1);
- to change the blinking digit of the parameter, press the "Value" button (figure
2.8.4);
- to select the high-order digit, press the "Parameter" button;
- to exit the programming mode of an unfixed parameter value, press the "Mode"
button twice;
- after exiting the specified mode (entering an unfixed parameter value), the digits
of the set parameter value stop blinking.
The newly set value is put the last in the list of allowed values for programming.
When the "Mode" button is pressed once in the programming mode, entering of an arbi-
trary parameter value is not possible.
When none of the buttons "Mode", "Parameter" or "Value" is pressed for seven seconds in
the mode of unfixed value input, the II automatically switches to the main multifunction in-
dicator operation mode, and all set parameter values are saved.
It is allowed to enter one unfixed parameter value in the following ranges:
- for "Z" – from 23 to 69;
- for "I" – from 1,000 to 4,000;
- for "R" – from 400 to 1000;
- for "KV2" – from 0.346 to 0.600;
- for "ZV"– from 12 to 99;
- for "V" – from 0 to 1000.
The list of programmed parameter values for tractors "BELARUS-2022.6" (graphic
examples of parameter presentations and their values on the multifunction indicator in the
programming mode) is given in Table 2.8.4.