5.4.1.10 Operation 9. Visual inspection of exhaust gases after-treatment device
Check visually condition of SCR system elements. If there are leakages or me-
chanical damages of SCR system elements, it is necessary to contact authorized service
center to eliminate detected faults.
5.4.1.11 Operation 10. Check of tire state
Carry out visual inspection of tires outside appearance and conditions in order to
detect faults or objects getting stuck in the tires (tacks, rocks and etc.). If necessary, clear
the tires of foreign objects. In case the tires have defects going up to the tire fabric or
cracks going through the whole tire thickness, dismount the tire and send it to the special
repair workshop for retreading. If the tires have defects beyond repair, replace the tire. A
defective tire shall be sent to recycling.
5.4.1.12 Operation 11. Check of air conditioner hose fixtures
Note – The operation shall be carried out while mounting of an air conditioner in-
stead of a fan-heater on the tractor.
Carry out visual inspection of air conditioner hose fixtures. Air conditioner hoses
shall be properly fixed with coupling clamps. The hoses shall not be in contact with moving
parts of the tractor.
5.4.1.13 Operation 12. Check of the hydraulic system elements
Carry out inspection of the tractor hydraulic system elements. In case condensation
and down-flows are detected, eliminate them by means of threaded joints tightening.
Change hoses and high pressure hoses having cracks, cuts or damages.
5.4.1.14 Operation 10. Check/cleaning of air conditioner drainage pipes from con-
densate water
"BELARUS-2022.6" tractors have two drainage conditioner pipes, which are lo-
cated under rear fenders (one pipe for each side), as shown in figure 5.4.8.
1 – rear fender; 2 – drainage pipe; 3 – middle cab support; 4 – rear wheel.
Water dropping from drainage pipes outputs during air-conditioner operation in the
hot weather is а sign of clean drainage pipes. If the water doesn't drop from drainage pipes
during air-conditioner in the hot weather it is necessary to blow drainage pipes with com-
pressed air.
Figure 5.4.8 – Location of drainage pipes outputs