Order Of Integrated Indicator Programming; Control Panel Of Integrated Indicator; Algorithm Of Integrated Indicator Programming - Belarus 1822.3 Operator's Manual

Table of Contents

Advertisement

3.21.3 Order of integrated indicator programming

3.21.3.1 Control panel of integrated indicator

The control panel 16 (figure 2.1.1) makes it possible to perform manual programming of the
indicator by means of "Parameter" and "Value" buttons (figure 3.21.1) and to change the mode of
displaying the parameters to be shown on the LCD.
A diagnostic connector
sible to perform automatic programming (reprogramming) of the integrated indicator (II) by means
of a special device (if provided). Should such a device be unavailable, the programming shall be
performed
by
means
1822.3/1822 .3/2022.3/2022 .3 " tractors, the

3.21.3.2 Algorithm of integrated indicator programming

Choosing a fixed value of a parameter when programming of the Integrated Indicator
shall be done in the following way:
- first pushing of the button "Parameter" (figure 3.21.1) switches the multifunctional In-
dicator 16 (figure 2.7.1) into the mode of viewing a designation of a programmable parameter
and its numeric value. Repeated pushings of the button "Parameter" changes parameters in a
cyclic way;
- sequential pushing of the button "Value" changes a numeric value of a preset pro-
grammable parameter;
- the programming mode is exited automatically when the buttons "Parameter" and
"Value" are not pushed within seven seconds.
When the programming mode is exited the last parameter values chosen with the but-
ton "Value" are stored.
To choose a non-fixed value of a parameter of the Integrated Indicator programming
the following shall be done:
- with the button "Parameter" (figure 3.21.1) choose a parameter, the value of which is
to be set;
- push the button "Mode" twice, after that on the multi-functional indicator 16 (figure
2.7.1) the least significant digit of a numeric value will start flashing;
- the flashing digit of a parameter is changed by pushing the button "Value";
- transit to the more significant digit is carried out by pushing the button "Parameter";
- the mode of programming a non-fixed value of any parameter is exited by double
pressing the button "Mode";
- after the given mode is exited (input of a non-fixed parameter value) digits of the set
parameter value stop flashing;
A newly entered value is set last in the list of parameter values permitted for program-
ming.
At single pressing the button "Mode" in the programming mode entering an arbitrary
value of a parameter is not possible.
If the buttons "Mode", "Parameter", "Value" are not pressed within seven seconds in the
mode of entering a non-fixed value, the Integrated Indicator transits automatically into the main
operation mode of the multifunctional indicator, storing the set parameter values.
It is allowed to enter one non-fixed value within the following ranges:
- for "Z"parameter: from 23 to 69;
- for "I"parameter: from 1.000 to 4.000;
- for "R"parameter: from 400 to 1000;
- for "K" parameter: from 2.360 to 4.000;
- for "KV2"parameter: from 0.346 to 0.600;
- for "ZV"parameter: from 12 to 99;
- for "V"parameter: from 0 to 1000.
Figure 3.21.1 – Control panel of integrated indicator
1, located on the front surface of the control panel, makes it pos-
of
the
above
https://tractormanualz.com/
mentioned
buttons.
1 connector is not enabled.
150
2022.3-0000010 OM
On
"BELARUS-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1822b.32022.32022b.3

Table of Contents