6.12 Possible failures of the hydrostatic steering control and instructions for
their troubleshooting
The list of possible failures of the hydrostatic power steering and instructions for
their troubleshooting are shown in Table 6.12.1.
Table 6.12.2
Failure,
external manifestation, cause
No pressure or insufficient pressure
in the steering control hydraulic sys-
tem (it shall be from 14.0 to 15.5
MPa (steering wheel is turned up to
the stop)) due to the following rea-
sons:
- HSC was not bled
- faulty adjustment of dosing pump
pressure relief valve (low pressure)
- faulty feed pump (the pump fails to
increase pressure because of low
efficiency factor)
Hard abrasion or blocking up in
steering column mechanical com-
ponents
Increased torque of FDA reduction
unit turn
Steering wheel is rotating without driven wheels turning
There is no oil in the tank
Improper
adjustment
pump valves. Adjusting pressure of
the pressure-relief valve exceeds
the pressure of anti-shock valves
Worn-out sealings of the hydraulic
cylinder piston
Deadlock
of
the
shockproof valve in an open posi-
tion
Steering is too slow and too hard while quick turning of steering wheel
Faulty feed pump (the pump fails to
increase pressure because of low
efficiency factor)
Improper
adjustment
pump pressure-relief valve (set to
low pressure or stuck in the open
position due to dirt accumulation)
Great effort at the steering wheel
Bleed the HSC hydraulic system by turning the
steering wheel moving guide wheels from left-most
to the right-most position (stop-to-stop position) for
2-3 times
Contact the dealer. Adjust the pressure relief valve
for the required pressure. The operation shall be
performed only by maintenance department
Contact the dealer for feed pump replacement or
repair
Stop abrasion in the steering column, for which do
the following:
- loosen upper nut;
- lubricate friction surfaces of plastic bushings;
- eliminate contact of universal-joint yoke with
steering column bracket walls
Make repair of FDA
Fill the tank with oil to the required level and bleed
air from the hydraulic system of HSC
of
dosing
Contact the dealer. Adjust the pressure-relief valve
and anti-shock valves to the required pressure. The
operation shall be performed only by maintenance
department
Repair or replace the hydraulic cylinder
dosing
pump
Rinse the shockproof valve
Contact the dealer for feed pump replacement or
repair.
of
dosing
Contact the dealer. Adjust the pressure relief valve
for the required pressure. The operation shall be
performed only by maintenance department.