The following parameters are displayed in information field 2 (figure 2.8.3):
- total elapsed engine time;
- instant fuel flow;
- on-board voltage;
- remaining fuel volume;
- time of running with remaining fuel;
- rear PTO speed;
- engine operating time for the specified period;
- testing of speed sensors workability;
- testing of frequency fuel volume sensor (FFVS) workability;
- testing of CAN-bus workability and connection to the Integrated Indicator.
Switching between indication modes of "Total elapsed engine time", "Instant fuel
flow", "Remaining fuel volume", "Time of running with remaining fuel", "On-board voltage",
"Rear PTO speed", and switching between messages on faults is carried out with "Mode"
button of the control panel (figure 2.8.2).
Samples of displaying operating parameters of the tractor on the multifunction dis-
play and their short description are given in table 2.8.2.
Table 2.8.2 – Samples of displaying operating parameters of the tractor on the mul-
tifunction display
Parameter
Total
elapsed
engine time, h
Instant fuel flow,
l/h
On-board
volt-
age, V
Remaining
fuel
volume
in
the
tank, l
Time of running
on
remaining
fuel, h
Rear
PTO
speed, rpm
Engine operating
time
for
the
specified period
Sample of displaying
parameter on the mul-
tifunction display
Parameter description
The counter accumulates information on the total
elapsed engine time with uploading a message
"engine speed" from the engine control unit and
stores it when the power supply is off. The range
of engine time indications is from 0 to 99999
hours.
In this mode a current value of the instant fuel flow
with a resolution of 0,1 l/h is displayed.
In this mode a current value of on-board voltage
with an accuracy of 0,1 V is displayed in a digital
form.
In this mode current fuel volume remaining in the
tank is displayed in liters.
This mode is available only when the tractor is
stopped (i.e. when there are no signals from the
speed sensors).
In this mode assessed engine time, calculated for
current values of the instant fuel flow and remain-
ing fuel volume is displayed
In this mode a precise speed of the rear PTO
shaft end extension depending on the signal from
the rear PTO speed sensor is displayed.
In this mode engine operating time for the speci-
fied period with an accuracy of 1/10 of an hour is
displayed. If necessary, it is possible to zero the
value of a meter by pressing the button "Mode"
and holding it pressed for at least 2 sec.