End of table 6.14.1
Failure, external manifestation,
cause
Spontaneous lifting of RLL (lifting without a command received from the instru-
Deadlock of the lift spool of a regu-
latory section ЕНR-23LS (if inte-
grated unit BOSCH is installed))
Deadlock of the lift spool of a regu-
latory section (if hydraulic unit
RP70-1523.1 is installed)
Failure diagnostics signaling device located on the RLL control panel reports nu-
Damage in electrical wiring, sole-
noids, corrosion of terminals, sen-
sors failure (force or position) of
RLL ECS.
ment panel or remote control buttons)
Elimination of failure should be carried out directly
in tractor, without the need of integrated unit disas-
sembly, for which perform the following:
- thread out four screws fastening lower solenoid
13 (Figure 7.13.1) then withdraw the solenoid ;
- withdraw the lift spool and the spring, rinse the
mentioned components and the bore in the section
housing;
- assemble the lift valve in the reverse sequence.
The failure shall be eliminated only by a dealer at a
service center!
To eliminate failure contact your dealer
merical error codes
Eliminate the failure according to the subsection
6.13 "Possible failures in the electronic control sys-
tem of RLL, and guidelines for troubleshooting"
215
2022.6-0000010 OM