Keykode Reader Communications Problems; Help Messages; General Messages - evertz 4025 Instruction Manual

Film footage encoder
Table of Contents

Advertisement

5.2.

HELP MESSAGES

SYSTEM DIAGNOSTICS

KeyKode Reader Communications Problems

SERIAL: FRAMING/OVERRUN ERR
SERIAL: PARITY ERROR
SERIAL: RECEIVE TIMEOUT 1
SERIAL: RECEIVE TIMEOUT 2
SERIAL: UNIDENTIFIED CMD
SERIAL: J-RECORD ENDING ERR

General Messages

NO NEW PROBLEMS
GENLOCK MISSING
NOVRAM 1ST BIRTHDAY
EVCOM RESET
STACK RESET
HARDWARE /SOFTWARE MISMATCH
VIDEO STD SWITCH PROBLEM
NOVRAM RETRY COUNT EXCEEDED
VCG OVERRUN
Model 4025 Film Footage Encoder Manual
Indicate problems with the serial input data from
the KEYKODE reader. These include
parity/baud problems and message format
problems.
Usually indicates DigiSync console set to Welch
Allyn Mod protocol. Set DigiSync to Welch Allyn
protocol (See manual section 8.3.2).
Indicates the 631 message has been reset and
no further problems have been detected.
The CHAR GEN IN video input is missing or
disturbed.
The Non-volatile memory has been reset to
factory defaults.
An inter-module communications reset occurred,
usually caused by a power on reset of one or all
the cards.
The 631 needed to do some software error
prevention - please call us if you get this
message.
The 615 has detected the firmware is
incompatible with the hardware.
The 615 was unable to switch video standards.
The nonvolatile memory was unable to be
programmed
Indicates an timing overrun related to the
character inserter. It is normal for this message
to occur after accessing the menu system.
Page 5-5

Advertisement

Table of Contents
loading