10.1 Electrical Data

10.1.1 Electrical Data, 380–480 V AC
Table 78: Electrical Data, Mains Supply 3x380–480 V AC
FC 202
High/normal overload
High overload=150% or 160% torque for a duration of 60 s. Normal
overload=110% torque for a duration of 60 s.
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Typical shaft output at 480 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 400 V) [A]
Intermittent (60 s overload) (at 400 V) [A]
Continuous (at 460/480 V) [A]
Intermittent (60 s overload) (at 460/480 V) [A]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Continuous kVA (at 480 V) [kVA]
Maximum input current
Continuous (at 400 V) [A]
Continuous (at 460/480 V) [A]
Maximum number and size of cables per phase
2
- Mains [mm
(AWG)]
- Mains with disconnect [mm
- Mains with fusible disconnect [mm
- Mains with contactor [mm
2
- Motor [mm
(AWG)]
Drive module power loss at 400 V [W]
Drive module power loss at 460 V [W]
Drive efficiency
(2)
(4)
Output frequency [Hz]
160 | Danfoss A/S © 2018.10
2
(AWG)]
2
(AWG)]
2
(AWG)]
(1) (2) (3)
(1) (2) (3)
N110
N132
HO
NO
HO
90
110
110
125
150
150
110
132
132
D9h
D9h
177
212
212
266
233
318
160
190
190
240
209
285
123
147
147
127
151
151
139
165
165
171
204
204
154
183
183
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2031
2559
2289
1828
2261
2051
0.98
0.98
0–590
0–590
AQ262141056213en-000101 / 130R0882
Specifications
N160
NO
HO
NO
132
132
160
200
200
250
160
160
200
D9h
260
260
315
286
390
347
240
240
302
264
360
332
180
180
218
191
191
241
208
208
262
251
251
304
231
231
291
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2954
2923
3770
2724
2089
3628
0.98
0–590