Electrical Data, 525-690 V Ac - Danfoss VLT AQUA Drive FC 202 Operating Manual

110-800 kw, enclosures d9h-d10h and e5h-e6h
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Operating Guide | VLT® AQUA Drive FC 202
3
See also Input Power Option Losses.
4
If using an output filter, the output frequency is limited further. See the Motor Output (U, V, W) section.
10.1.2 Electrical Data, 525–690 V AC
Table 82: Electrical Data, Mains Supply 3x525–690 V AC
FC 202
High/normal overload
High overload=150% or 160% torque for a
duration of 60 s. Normal overload=110% tor-
que for a duration of 60 s.
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 525 V) [A]
Continuous (at 575/690 V) [A]
Maximum number and size of cables per phase
2
- Mains [mm
(AWG)]
- Mains with disconnect [mm
- Mains with fusible disconnect [mm
- Mains with contactor [mm
2
- Motor [mm
(AWG)]
Drive module power loss at 600 V [W]
Drive module power loss at 690 V [W]
Drive efficiency
(2)
Output frequency [Hz]
(4)
Danfoss A/S © 2018.10
N110
HO
75
100
90
D9h
113
170
108
162
103
108
129
109
104
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2
(AWG)]
2x95 (2x3/0 mcm)
2
(AWG)]
2
2x95 (2x3/0 mcm)
(AWG)]
2x95 (2x3/0 mcm)
1430
(1) (2) (3)
1480
(1) (2) (3)
0.98
0–590
N132
NO
HO
NO
90
90
110
125
125
150
110
110
132
D9h
137
137
162
151
206
178
131
131
155
144
197
171
125
125
147
131
131
154
157
157
185
132
132
156
126
126
149
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
2x95 (2x3/0 mcm)
1740
1742
2101
1798
1800
2167
0.98
0–590
Specifications
N160
N200
HO
NO
HO
110
132
132
150
200
200
132
160
160
D9h
D10h
162
201
201
243
221
301
155
192
192
233
211
288
147
183
183
154
191
191
185
230
229
156
193
193
149
185
185
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2x95 (2x3/0 mcm)
2x185 (2x350 mcm)
2080
2649
2361
2159
2740
2446
0.98
0.98
0–590
0–590
AQ262141056213en-000101 / 130R0882 | 165
NO
160
250
200
253
278
242
266
230
241
289
244
233
3074
3175