Danfoss VLT AQUA Drive FC 202 Operating Manual page 166

110-800 kw, enclosures d9h-d10h and e5h-e6h
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Operating Guide | VLT® AQUA Drive FC 202
FC 202
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
PHF overtemperature trip [°C (°F)]
dU/dt filter overtemperature trip [°C (°F)]
Sine-wave filter overtemperature trip [°C (°F)]
1
Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions.) These values are based on a typical motor
efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies to dimensioning of drive cooling. If the switching frequency is higher than the default
setting, the power losses can increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/
knowledge-center/energy-efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B
each add only 4 W.
2
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency class, see the Ambient Conditions
section. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
3
See also Input Power Option Losses.
4
If using an output filter, the output frequency is limited further. See the Motor Output (U, V, W) section.
Table 83: Electrical Data, Mains Supply 3x525–690 V AC
FC 202
High/normal overload
High overload=150% or 160% torque for a duration of 60 s.
Normal overload=110% torque for a duration of 60 s.
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 525 V) [A]
Continuous (at 575/690 V) [A]
Maximum number and size of cables per phase
2
- Mains [mm
(AWG)]
166 | Danfoss A/S © 2018.10
N110
N132
110 (230)
110 (230)
80 (176)
80 (176)
150 (302)
150 (302)
150 (302)
150 (302)
150 (302)
150 (302)
N250
HO
160
250
200
D10h
395
380
242
363
230
241
289
381
366
2x185 (2x350 mcm)
N160
110 (230)
80 (176)
150 (302)
150 (302)
150 (302)
N315
NO
HO
NO
200
200
250
300
300
350
250
250
315
D10h
303
303
360
333
455
396
290
290
344
319
435
378
276
276
327
289
289
343
347
347
411
453
413
504
434
395
482
2x185 (2x350 mcm)
AQ262141056213en-000101 / 130R0882
Specifications
N200
110 (230)
80 (176)
150 (302)
150 (302)
150 (302)
N400
HO
NO
250
315
350
400
315
400
D10h
360
418
540
460
344
400
516
440
327
380
343
398
411
478
504
574
482
549
2x185 (2x350 mcm)