Setting The Program Source; Using Process Functions; Monitoring Your Process - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy
1. Press SUPPLY → PANEL → CLICKS.
2. Rotate the MODIFY knob to set the number of counts per click.
3. Press ENTER to accept and exit.

Setting the Program Source

SUPPLY → PGM_SRC
The program source (PGM_SRC) feature specifies for each control mode the program source
for regulation mode and setpoint information. For each control mode, if the program source is
set to internal (INT), the Pinnacle supply uses the information for output regulation mode and
setpoint that has been established through either the Pinnacle Remote Active panel or the
Standard Serial port. If the program source is set to external (EXT), the Pinnacle supply uses
the setpoint and output regulation mode that has been established through the pins on the User
port.
To select the desired source and type, follow these steps:
1. Press SUPPLY → PGM_SRC.
HOST, LOCAL, and USER options appear. Press one of these buttons to toggle between
internal and external for that types.
2. Press EXIT.
Note: A user card must be installed in order to alter these settings.

USING PROCESS FUNCTIONS

Use this option to access parameters that control, limit, or monitor your process. The menu
options are:
• MONITOR: monitor your process
• LIMITS: set limits
• ARC: set arc parameters
• CONTROL: set process control parameters

Monitoring Your Process

PROCESS → MONITOR
This menu allows you to monitor elements of your process such as the life of your target, how
long the process is running out of setpoint, or whether the process voltage drops below its
threshold.
4-28
Page 62 of 182
®
I/O Communication and Control
5702199-A