Changing The Target Functions - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy
To enable the out-of-setpoint timer, follow these steps to select a value (in 0.1 s increments).
To disable the timer, follow these steps and select a value of 0.
Note: Because the readbacks, which are compared to the setpoint, are filtered in the software,
we recommend you do not use this feature for process runs that are less than 1 s.
1. Press PROCESS → MONITOR → SETPT.
2. Rotate the MODIFY knob to adjust the value.
3. Press ENTER to accept and exit.

CHANGING THE TARGET FUNCTIONS

PROCESS → MONITOR → TARGET
The target functions let you enable or disable the target life counter (ENABLE), change the
active target (SELECT), and set the target life (LIFE) in 0.01 KWh increments.
PROCESS → MONITOR → TARGET → ENABLE
To enable or disable the target life counter for the selected target, follow these steps:
1. Press PROCESS → MONITOR → TARGET → ENABLE.
2. Rotate the Modify knob to select Yes or No.
3. Press ENTER to accept and exit.
PROCESS → MONITOR → TARGET → SELECT
To change the active target life counter, follow these steps:
1. Press PROCESS → MONITOR → TARGET → SELECT.
2. Rotate the MODIFY knob to select the active target number.
3. Press ENTER to accept and exit.
Note: The User port has priority in selecting targets. Thus, if your unit has a user card
PROCESS → MONITOR → TARGET → LIFE
To set the target life in 0.01 kWh increments, follow these steps:
1. Press PROCESS → MONITOR → TARGET → LIFE.
2. Rotate the MODIFY knob to select a target life between 0 and 15000.00 kWh (The default
is 0).
4-30
Page 64 of 182
®
installed, you must set the target to 1 at the User port if you want to select targets
from the serial port, active front panel, or Pinnacle Remote Active Panel (that is,
when the Pinnacle unit is in host or local control mode). Leaving the target bits
open or leaving the User port pins unconnected causes the target selection at the
User port to default to 1.
I/O Communication and Control
5702199-A

Hide quick links: