Error Code Troubleshooting Table - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy

Error Code Troubleshooting Table

Use the following table to trouble shoot error codes.
Table 7-4. Error Codes
Error Code and
Message
Control Circuit Fault
A: Out of Setpoint Timer
(explicit clear)
Bus Fault
(explicit clear)
Bus Not Ready
(explicit clear)
7-8
Page 162 of 182
®
Problem Indicated
E000
The DSP failed to respond to
the processor.
E001
The out of setpoint timer has
expired.
Expired
E002
The buses have failed,
probably due to an ac input
power problem.
E003
The bus failed to power up
when the contactor closed,
probably due to an ac input
power problem.
Troubleshooting and Customer Support
Suggested Action
Power the unit off and then
back on. If the problem
persists, call AE Global
Support.
Increase the setpoint timer
value or disable the timer by
setting it equal to 0. If the
problem persists, check your
process parameters for
limiting factors. That is,
ensure that your load
impedance matches the
impedance range of the
Pinnacle unit. (See the
"Specifications" chapter for
an impedance range graph.)
Using all applicable safety
precautions, inspect your ac
input power source to ensure
that it is properly connected
and that the specified voltage
is being applied to the
Pinnacle unit. (See the
"Specifications" chapter for
ac input power
specifications.)
Using all applicable safety
precautions, inspect your ac
input power source to ensure
that it is properly connected
and that specified voltage is
being applied to the Pinnacle
unit. (See the "Specifications"
chapter for ac input power
specifications.)