Advanced Energy Pinnacle 20 kW Manual page 111

Table of Contents

Advertisement

Table 4-18. Host Port Commands
Command
159
Ramp time
remaining
160
request status
161
request
output on
status
5702199-A
Page 111 of 182
Description
Requests how much ramp time is
remaining. Returning packet contains 2
data bytes (16 bits), indicating how many
10 ms intervals remain.
Requests the status of the logic board.
The information in the returning packet is
used by AE Customer Service.
Requests the status of most recent output
on sequence; the returning packet
contains 1 data byte (8-bit value):
• 0 = output on sequence OK.
• 1 = control mode invalid.
• 2 = unit is already on.
• 7 = active fault exists.
• 11 = bus is not ready.
• 16 = end of target life event.
• 44 = the Pinnacle unit has not
received a request to turn output on
since power up.
I/O Communication and Control
Pinnacle™ 20 kW
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
2
0
6
0
1
4-77

Hide quick links:

Advertisement

Table of Contents
loading