5. Press ENTER to accept and exit.
Table 4-10. Strike Voltage Limit
Strike
Voltage
Setting
Low
Medium
High
SETTING A MAXIMUM LIMIT FOR OUTPUT VOLTAGE
PROCESS → LIMITS → VOLTAGE
This function lets you set a maximum limit for output voltage. The maximum allowable value
is the maximum rated output for the supply. Accuracy is +0.3% of the full rated output voltage
for the supply.
To set the user voltage limit, follow these steps:
1. Press PROCESS → LIMITS → VOLTAGE.
2. Rotate the MODIFY knob to select a value between 0 and the maximum rated output
voltage for the supply.
3. Press ENTER to accept and exit.
SETTING THE MAXIMUM LIMIT FOR OUTPUT CURRENT
PROCESS → LIMITS → CURRENT
This function lets you set a maximum limit for output current. The maximum allowable value
is the maximum rated output for the supply. Accuracy is +0.3% of the full rated output current
for the supply.
To set the user current limit, follow these steps:
1. Press PROCESS → LIMITS → CURRENT.
2. Rotate the MODIFY knob to select a value between 0 and the maximum rated output
current for the supply.
3. Press ENTER to accept and exit.
Note: Master/slave units will refresh to the maximum limit for current on power up, after
explicit slave faults, or after connecting or disconnecting slaves.
SETTING THE MAXIMUM LIMIT FOR OUTPUT POWER
PROCESS → LIMITS → POWER
4-32
Page 66 of 182
®
Low-Z
Standard-Z
200–400 Vdc
400–800 Vdc
400 V ± 100 V
800 V ± 100 V
650 V ± 100 V
1,100 V ± 100 V
900 V ± 100 V
1,450 V ± 150 V
I/O Communication and Control
High-Z
High Voltage
400–1000 Vdc
750–1500 Vdc
500–1000 Vdc
1500–3000 Vdc
1,000 V ± 100 V
Strike voltage not
1,200 V ± 100 V
available
1,450 V ± 150 V