Figure 4-2. Devicenet - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Table 4-18. Host Port Commands
Command
192
request arc
average
window
length
195
request
personality
card
197
request flash
configuration
198
request s/w
rev level—
mainframe
5702199-A
Page 119 of 182
Description
Requests the length of the arc average
window; returning packet contains 1 data
byte (8-bit value) indicating the number
of seconds over which arc counts are
being averaged.
Set this value with Command 7.
Requests the identity of the unit's
personality cards. The returning packet
contains 2 data bytes:
• first byte = identity of card in slot 1
– 0 = card not present
– 01 or 17 = dual User port
– 03 or 26= Profibus
– 05 or 21 = single User port
– 30 = DeviceNet
• second byte = identity of card in
slot 2
– 0 = card not present
– 03 or 26 = Profibus
– 04 = Host Protocol Translator
– 05 or 21 = single User port
– 18 or 28 = AE Bus
– 22 or 29 = master/slave card with
AE Bus
Requests the version level of the unit's
flash memory; returning packet contains
32 data bytes.
Requests the revision level of the
mainframe software; the returning packet
contains 12 ASCII characters.
I/O Communication and Control
Pinnacle™ 20 kW
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
1
0
2
0
32
0
12
4-85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents