Table 3-3. Electrical Specifications - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Table 3-3. Electrical Specifications

High- and Low-Frequency
Output Ripple Voltage
Accuracy of All Analog
Signals
Power Factor
Standard Output Range (full
power)
Usable Output Range
Impedance Range
Accuracy of User-Defined Limits
Current
Voltage
Power
Readback Accuracy
Ignition Capability
5702199-A
Page 29 of 182
If you have a supply with a single inverter (a 6 kW or
10 kW unit), the component of output voltage ripple as
related to input line frequency is less than 2% rms.
If you have a supply with a single output but dual
inverters (a 12 kW or a 20 kW unit) high-frequency
output ripple options are selectable from the active front
panel, Pinnacle Remote Active Panel, or serial (Host)
port. The "high" option is 4 to 5% rms; the "low" option
is less than 2% rms.
±1% of the actual value (V, kW, or A) or ±0.2% of the
full scale value, whichever is greater
> 0.9 for loads greater than 1.2 kW
20 kW over the 400-to-1000-Vdc range, with a
maximum current of 50 A
See Figure 3-1 on page 3-7.
See Figure 3-2 on page 3-8.
0 to 5% over the limit from 10 to 100% of full rated
output
0 to 5% over the limit from 10 to 100% of full rated
output
0 to 5% over the limit from 10 to 100% of full rated
output
Power is displayed as a simple multiplication of P=V*I.
With supplies operated in low impedance loads (high
current), a simple 1 V change could induce up to a 50 W
change in power. Therefore, the readback accuracy may
be greater than 1% in low impedance situations.
Selectable from the active front panel, Pinnacle Remote
Active Panel, and serial (Host) port
Voltage clamped to 1500 V at 60 mA maximum
Specifications
Pinnacle™ 20 kW
3-5