The Pinnacle unit examines the ramping-to-setpoint rate only if the output power setpoint has
been set to a new value. Ramping will begin again at 0 after an off-on sequence has occurred.

RESPONSE MESSAGE

The following table represents the structure of the response message.

Table 4-4. Structure of the poll command message

Byte
Bit 7
0
1
2
3
4
5
6
7
8
Note: The 16-bit Power Output value (AI) is shifted right four bits, and the remaining four bits
are filled with 0s. This changes the 16-bit AI to a 12-bit AI with a value of 10 V =
OFFF
Note: For Byte 8, the abbreviations have the following meanings:
• POS stands for Power On Status: 1 = output on; 0 = output off
• SPS stands for Setpoint Status: 1 = setpoint reached; 0 = setpoint not reached
• TS stands for Temperature Status: 1 = good; 0 = over-temperature condition
• ARCD stands for Arc Detected: 1 = on; 0 = off
• INTS stands for Interlock Status: 1 = satisfied; 0 = open
Scaling
Parts of the Message structure are based on binary representation of analog voltages. Thus
they have analog scaling associated with them.
The scaling for power output is 0 to 10 V, where 10 V = the full rated output power capability
of the Pinnacle power system (master and slave units). The read back is limited to 10 V
(0FFF
), even in those cases where output may temporarily exceed the maximum output
hex
capability of the power system.
4-8
Page 42 of 182
®
Bit 6
Bit 5
0*
0*
0*
0*
0*
0*
0*
0*
0*
Ramp Rate Setpoint AI (LSB)
0*
0*
0*
.
hex
I/O Communication and Control
Bit 4
Bit 3
Power Output AI (LSB)
0*
Power Output AI (MSB)
Voltage Output AI (LSB)
0*
Voltage Output AI (MSB)
Current Output AI (LSB)
0*
Current Output AI (MSB)
0*
Ramp Rate Setpoint AI (MSB)
INTS
ARCD
Bit 2
Bit 1
Bit 0
TS
SPS
POS
5702199-A