Table 4-18. Host Port Commands
Command
163
request
config status
164
request
setpoint/
regulation
mode
5702199-A
Page 113 of 182
Description
Requests the system configuration status;
the returning packet contains 2 data bytes
(see the following illustration).
1st status byte:
0 = host program source
(0 = internal, 1 = external)
1 = local program source
(0 = internal, 1 = external)
2 = analog program source
(0 = internal, 1 = external)
3 = master unit
4 = slave unit
5 = arc handling
(0 = disabled, 1 = enabled)
6 = program source (0 = internal,
1 = external)
7 = target life status (0 = inactive,
1 = active)
2nd status byte:
0 = frt panel status (0 = not present,
1 = present)
1 = frt panel access (0 = unlocked,
1 = locked)
2 = joule mode (0 = disabled,
1 = enabled)
3 = contactor status (0 = open,
1 = closed)
4 = process voltage limit
(0 = disabled, 1 = enabled)
5 = ramp mode (0 = disabled,
1 = enabled)
6 = TCC status (0 = disabled,
1 = enabled)
7 = ripple level (0 = low, 1 = high)
Requests the setpoint level set by
Command 6 by whichever method of
output regulation has been selected (set
by Command 3); the returning packet
contains 3 data bytes:
• first/second byte (16-bit value) =
setpoint level
• third data byte (8-bit value) =
regulation mode (6 = power; 7 =
voltage, 8 = current)
I/O Communication and Control
Pinnacle™ 20 kW
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
2
0
3
4-79