Table 4-18. Host Port Commands
Command
60
ripple level
61
arc handling
enable/
disable
5702199-A
Page 103 of 182
Description
Sets the high-frequency output ripple to
either a low amplitude ripple (less than
2% rms) or a high amplitude ripple (4 to
5% rms). Send 1 data byte (8-bit value):
• 0 = low ripple
• non-zero value = high ripple
Read back this value with Command 163.
Enables or disables arc handling features.
Send 1 data byte (8-bit value):
• 0 = disable
• non-zero = enable
Read back this value with Command 163.
Note: Cycling power to the unit resets
arc handling mode to enabled.
See warning on page -26.
I/O Communication and Control
Pinnacle™ 20 kW
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
1
CSR only
1
CSR only
4-69