Error E081 Fault Vector; Slave Status Low Byte - Advanced Energy Pinnacle 20 kW Manual

Table of Contents

Advertisement

Advanced Energy

Error E081 Fault Vector

The Master/Slave fault vector associated with error code E081 E81 contains three hex bytes,
separated into one two-byte word and a one-byte word (see Command 135 of the AE Bus
command list). The two-byte word is a bit-wise "or" of all the slave unit errors; thus if a bit is
set, the error exists in one or more slaves.
Note: If your Pinnacle master unit features an active panel, you can view error code
information for each slave by turning the MODIFY knob.)
The one-byte word describes the faults in the communication bus between the master and
slaves.
The three hex bytes are displayed in this order from left to right: slave status high byte, slave
status low byte, personality card status byte. The bit definitions of these bytes are as follows:

SLAVE STATUS LOW BYTE

BIT 7 6 5 4 3 2 1 0
|
| | | |
|
| | | |
|
| | | |
|
| | | |................ Momentary power failure
|
| | |......................Pre-defined interrupt
|
| |...........................Xilinx detected fault
|
|...............................Reserved
|.....................................Reserved
7-16
Page 170 of 182
®
| | | Setpoint status 0=ok, 1=out of setpoint
| |......Bus fault
|...........Inverter low fault
Troubleshooting and Customer Support
5702199-A