Table 5-3. Input Sequences for Master and Slave Units
Acceptable
Sequence
for ...
Powering down
the master/slave
power supply
system
5702199-A
Page 145 of 182
Condition
Condition
of Master
of Slave
Unit's AC
Unit's AC
Input
Input
ac input
Switching ac
power is OFF
input power
OFF
Switching ac
ac input
input power
power is ON
OFF
Switching ac
ac input
input power
power is ON
OFF
ac input
Switching ac
power is ON
input power
OFF
ac input
Switching ac
power is ON
input power
OFF
Installation
Pinnacle™ 20 kW
Condition
Response (Type of
of Output
Fault)
Off by
No fault
default
(Master ac
input power
is OFF)
Off
Slave unit experiences
a self-clearing fault
and then waits for the
master unit
On
Slave unit experiences
a self-clearing fault
and then waits for the
master unit
Off
If the slave remains
off, this results in an
explicit-clear fault; the
master unit re-scales
system output after the
fault has cleared and
you have
acknowledged the
condition.
powers on again, this
results in a self-
clearing fault.
On
If the slave remains
off, this results in an
explicit-clear fault; the
master unit re-scales
system output after the
fault has cleared and
you have
acknowledged the
condition. If the slave
powers on again, this
results in a self-
clearing fault
a
b
If the slave
5-17