Advanced Energy
Table 4-18. Host Port Commands
Command
165
request
actual power
166
request
actual voltage
167
request
actual
current
168
request
actual power,
voltage,
current
169
request
setpoints:
power,
voltage, and
current
4-80
Page 114 of 182
®
Description
Requests a snapshot of the output power
level at that instant; the returning packet
contains 2 data bytes (16-bit value)
indicating power level in kilowatts.
Assume 3 decimal places for a stand-
alone unit (1000 = 1.000 kW) and 2
decimal places for a master/slave unit
(1000 = 10.00 kW). Please refer to the
"Specifications" chapter of this manual
for your unit's capabilities.
Requests a snapshot of the output voltage
level at that instant; the returning packet
contains 2 data bytes (16-bit value),
indicating the voltage level. For example
a value of 800 would indicate 800 V (no
implied decimal).
Requests a snapshot of the output current
level at that instant; the returning packet
contains 2 data bytes (16-bit value). Two
decimal places are implied. For example,
a value of 1500 indicates 15.00 A.
Requests a snapshot of the output power,
voltage, and current at that instant; the
returning packet contains 6 data bytes:
• first/second byte = power level
• third/fourth byte = voltage level
• fifth/sixth byte = current level
Refer to Commands 165, 166, and 167
for the format of the reported output
values
Requests the setpoint levels for power,
voltage, and current; the returning packet
contains 6 data bytes (three 16-bit
values). Refer to Commands 165, 166,
and 167 for the format of the reported
setpoint values.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
2
0
2
0
2
0
6
0
6