The scaling for voltage output is 0 to 10 V, with 10 V = 1,000 V. The read back is limited to 10
V (0FFF
hex
The scaling for current output is 0 to 10 V, with 10 V = the maximum output current capability
of the unit. The read back is limited to 10 V (0FFF
temporarily exceed the maximum output current capability.

EXPLICIT MESSAGING

The Pinnacle DeviceNet interface supports explicit messaging so that you can receive
information about two power system parameters: maximum power and maximum current. Use
the following Class Code 64 (40
Attribute
6
7
Note: The Max Power attribute returns a value in Watts if the unit is operating stand alone. For
example, a value of 20,000 equates to 20,000 W. The Max Power attribute scaling is
Watts x 10 if the unit is operating as a master/slave set. In this case, a value of 2,000
equates to 20,000 W.
Note: The Max Current attribute returns a value in Amperes with 2 decimal places implied.
For example, a value of 8,000 equates to 80 A.
For more information about this type of messaging, refer to section 4-2 of the DeviceNet
Specification (version 2.0 or later). The following Common Services specifications apply:
Service Code
14 (0E
hex

Rear Panel LEDs

The rear panel of the Pinnacle unit features two bi-color LEDs (see Figure 4-3). One is labeled
MOD and indicates module status. The other is labeled NET and indicates network status.
5702199-A
Page 43 of 182
), even in those cases where output may temporarily exceed 1,000 V.
), Instance 1 attributes to retrieve this information:
hex
Access
Get
Max Power
Get
Max Current
Class
)
Yes
I/O Communication and Control
), even in those cases where output may
hex
Name
Type
UINT
UINT
Instance
Yes
Pinnacle™ 20 kW
Value
(1)
(2)
Service Name
Get_Attribute_Single
4-9