• H: Hard arc counting enabled
• Q/T/R: Recipe queue, TCC mode, or ramp enabled
• C/P: Custom or predefined arc handling enabled
– Warning field
Warning field: flashes "EOTL" when end of target life or "ARCLIM" when the arc
limit is reached.
Note: ARCLIM is only active when the Hard Arc Counting feature is enabled.
– Clock ID: what the supply is doing
• RMP = output is on and ramping
• RUN = output is on and the clock shows the elapsed time
• TCC = output is off and the TCC mode timer is active
• OFF = output is off and the clock shows the last run time
– Clock

Soft Keys

Use the soft keys to select whichever menu functions are shown immediately above them on
the two-line display. "Understanding the Menu Options" on page 4-20 explains how to
perform these operations from the Pinnacle control panel.
Note: If you're at the top level, press the MENU soft key to make the menus appear.

Modify Knob

Use the MODIFY knob with the soft keys to change selections and modify values that appear
on the two-line display.

CONTROL PANEL CONTROLS

Use the MODIFY knob and the five unlabeled soft keys that are directly below the display to
select parameters and modify values. To changes parameters using the menu, the Pinnacle unit
must be in local control mode (the LOCAL LED will be lit).
Note: When the Pinnacle unit is in User or Serial mode, you can view all the menu items, but
you cannot modify any of the items or lock the unit. If you switch the Pinnacle unit to
User mode while you are viewing an item in the menu, you are returned to the output
display screen immediately.
Press the MENU soft key when the top level display screen is displayed to cause the main
menu to appear. The main menu contains three menu selections, which are shown in Figure 4-
6. Generally, pressing a soft key causes another level of menu choices to display (for example,
MONITOR, LIMITS, ARC, and CONTROL display if you press the PROCESS soft key).
5702199-A
Page 53 of 182
I/O Communication and Control
Pinnacle™ 20 kW
4-19