Table 4-18. Host Port Commands
Command
31
out-of-
setpoint timer
32
ramp start
point
(percentage
of setpoint)
38
reset arc
density/run
counters
40
serial (Host)
port time-out
value
44
panel text
line 1
45
panel text
line 2
46
erase panel
text
4-66
Page 100 of 182
®
Description
Enables or disables an out-of-setpoint
timer and specifies how long you want
the power supply to tolerate an out-of-
setpoint condition before shutting off
output. To enable the timer, send a value
(2 bytes) between 1 and the maximum
value for your unit. One decimal is
implied (25 = 2.5s). To disable the timer,
send a value of 0. Read back this value
with Command 187.
Sets the ramp start point as a percentage
of setpoint when output is turned on.
Range is 0 to 95%. Send 1 byte with a
value of 0 to 95.
Read back this value with Command 152.
Resets micro-arcs-per-run and hard-arcs-
per-run counters to 0. These counters can
be reset at any time, and resetting them
can be useful for measuring arcs over a
specific period of time.
Specifies the amount of time the Pinnacle
supply waits between bytes from the
host. Send 2 data bytes (16-bit value); the
value represents increments of 10 ms; it
must be at least 2 but no greater than 500
(20 ms to 5 s) Two decimal places are
implied (enter 500 for 5.00). Read back
this value with Command 140.
Lets you write up to 40 characters of text
to line one (top line) of an active control
panel
Lets you write up to 40 characters of text
to line two (bottom line) of an active
control panel
Erases text displayed with commands 44
and 45 and refreshes the display.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
2
CSR only
1
CSR only
0
CSR only
2
CSR only
0 to 40
CSR only
0 to 40
CSR only
0
CSR only
5702199-A