Advanced Energy
Table 4-18. Host Port Commands
Command
20
recipe
regulation
mode
21
recipe ramp
time
4-62
Page 96 of 182
®
Description
Specifies the regulation mode for a recipe
step. Send two data bytes as follows:
• first byte = recipe step (must be a
value greater than 0 but no greater
than 8)
• second byte = regulation mode:
6 = power
7 = voltage
8 = current
Read back these values with Command
182.
Specifies the length of ramping time for a
recipe step (that is, how long the unit will
take to reach the setpoint you have
defined for the selected recipe step). Send
three data bytes arranged as follows:
• first byte = recipe step (must be a
value greater than 0 but no greater
than 8)
• second and third bytes = value
between 5 and 60,000 (or between
0.05s and 600 s); two decimal places
implied.
Note: If the unit has the 100 ms
feature, one decimal is
implied.
Read back these values with Command
181.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
2
CSR only
3
CSR only
5702199-A