Advanced Energy Pinnacle 20 kW Manual page 90

Table of Contents

Advertisement

Advanced Energy
Table 4-18. Host Port Commands
Command
4
joule setpoint
5
joule mode
enable
6
setpoint
4-56
Page 90 of 182
®
Description
Specifies the number of joules to be
delivered. Send a 4-byte (32-bit value);
the value must be between 0 and
9,999,999. Read back this value with
Command 173.
Enables or disables joule mode. Send 1
data byte (8-bit value): 0=disable non-
zero value = enable Read back this value
with Command 153.
Specifies the output setpoint level for
whichever method of regulation mode
has been selected. Send 2 data bytes (16-
bit value); an output power value implies
3 decimal places for a stand-alone unit
and 2 decimals for a master/slave unit.
An output current value should imply 2
decimal places, and an output voltage
value should imply 0 decimal places. For
example, for a 6 kW, standard Z stand-
alone supply, send a value between 0 and
6000 (6.000 kW, decimal is implied), or
0 and 1500 (15.00 A, decimal is implied),
or 0 and 800 (maximum output voltage).
Please refer to the Specifications Chapter
of this manual for your unit's capabilities.
Note: If the ramp feature is enabled
(Commands 15 and 16), sending
this command while the output is
on will force the unit to ramp from
the existing setpoint to the new
requested setpoint over the time
specified in Command 16. Thus,
by using this command and
Commands 15 and 16, you can
generate an output wave form
during a process.
Read back this value with Command
164.
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
4
CSR only
1
CSR only
2
CSR only
5702199-A