Advanced Energy Pinnacle 20 kW Manual page 110

Table of Contents

Advertisement

Advanced Energy
Table 4-18. Host Port Commands
Command
152
request ramp
start setpoint
percentage
153
request joules
status
154
request
regulation
mode
155
request
control mode
156
request active
target
number
157
request target
life
158
request ramp
time
4-76
Page 110 of 182
®
Description
Requests the ramp start setpoint
percentage set with Command 32;
returning packet contains 1 data byte (8-
bit) between 0 and 95 (%).
Requests joule mode status set with
Command 5; the returning packet
contains 1 byte:
• 0 = inactive
• non-zero value = active
Requests the output regulation mode set
by Command 3; the returning packet
contains 1 data byte (8-bit value):
• 6 = power
• 7 = voltage
• 8 = current
Requests control mode (set by Command
14); the returning packet contains 1 data
byte (8-bit value):
• 2 = serial (Host) port
• 3 = an active control panel (Local)
• 4 = User port
Requests an indication of the active
target set by Command 11; the returning
packet contains 1 data byte indicating
target 1, 2, 3, 4, 5, 6, 7, or 8.
Requests the amount of target life time
set by Command 12 remaining for the
target you specify. Send 1 data byte
indicating which target; the returning
packet contains 4 data bytes (32-bit
value) indicating the time remaining in
kilowatt-hours. Two decimal places are
implied. For example, a value of 100
indicates 1 kWh.
Requests ramp time set with Command
16. Returns a 2-byte value (16 bits)
indicating a ramp time of 5 (50ms) to
60,000 (600.00 s).
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
1
0
1
0
1
0
1
0
1
1
4
0
2