Table 4-18. Host Port Commands
Command
162
request
process status
4-78
Page 112 of 182
®
Description
Requests a report on process status; the
returning packet contains 4 data bytes
(see the following illustration).
1st status byte:
0 = Arc handling (0 = custom,
1 = predefined metal or non-
metal)
1 = Ramp is active
2 = Run is active
3 = Output power (0 = off, 1 = on)
4 = Illegal regulation mode
5 = Cable interlock
6 = End-of-target-life event
7 = Setpoint status (0 = within
tolerance, 1 = out-of-tolerance)
2nd status byte:
0 = User port auxiliary interlock
1 = User port vacuum interlock
2 = User port water interlock
3 = Control circuit fault
4 = Heat sink over-temp event
5 = User interlock open
6 = User port reset active
7 = Main contactor interlock open
3rd status byte:
0 = Momentary power failure
1 = Master/slave fault
2 = Unassigned
3 = Unassigned
4 = Side A inverter low
5 = Side B inverter low
6 = Unassigned interrupt event
7 = Profibus error
4th status byte:
0 = Bus fault
1 = Process voltage low
2 = Joules reached
3 = Unassigned
4 = Out-of-setpoint timer expired
5 = Ground fault
6 = Unassigned
7 = Unassigned
I/O Communication and Control
Number of
Number of
Transmit
Response
Data Bytes
Data Bytes
0
4
5702199-A