Advanced Energy
Table 7-1. Help Codes
Help Code
H006
AEBus: Data Byte
Count Incorrect
H007
User Port has Priority
H008
Target Conditioning Is
Active
H009
User Port Reset Is
Active
H010
Host Port: Reset
Asserted
H011
Arc Handling Disabled
H013
Ramp Feature
Disabled
H015
TCC Mode Enabled
H017
Ramp Mode Enabled
H019
Recipes Enabled
H020
User port standby.d
is active
7-4
Page 158 of 182
®
Problem Indicated
The number of data bytes
sent by the Host via AE Bus
is incorrect.
The User port is overriding
your command request.
The requested action could
not be performed while TCC
is active.
User port "reset" line is
active.
An AE Bus command 119
was received.
The requested action could
not be performed, because
the Arc Handling feature is
disabled.
The requested action could
not be performed, because
the ramp feature is disabled
The requested action could
not be performed, because
the TCC feature is enabled.
The requested action could
not be performed because
the ramp feature is enabled.
The requested action could
not be performed because
the recipe feature is enabled.
The standby.d line on the
User port has been asserted.
Troubleshooting and Customer Support
Suggested Action
Review the AE Bus
command list.
Disable User port feature for
the command you desire.
Wait until unit exits TCC
mode.
De-assert User port "reset"
line.
No action.
Enable Arc Handling.
Enable the ramp feature.
TCC, Ramp, and Recipe
features are mutually
exclusive. Disable the TCC
feature and repeat the
action.
TCC, Ramp, and Recipe
features are mutually
exclusive. Disable the Ramp
feature and repeat the
action.
TCC, Ramp, and Recipe
features are mutually
exclusive. Disable the
Recipe feature and repeat
the action.
Review user port
functionality and
assert/de-assert standby.d
as needed.
5702199-A